Natural ventilation: what our sensors measured over twelve months
We instrumented three buildings in Niamey. The results challenge a few certainties.

For twelve months we installed 34 temperature, humidity and CO₂ sensors in three buildings: a compressed-earth-block villa, a double-skin office building, and — as a control — a glazed building with permanent air conditioning.
Finding 1: mass beats insulation
In a Sahelian climate, the comfort gap comes not from the wall's thermal resistance but from its mass. The 40 cm earth-block wall (low R, high mass) stayed consistently more comfortable than a lightweight insulated wall of the same R.
Finding 2: the night does all the work
In the naturally ventilated building, 78% of effective cooling happens between 10 pm and 6 am. In other words: a badly designed night-ventilation strategy cancels every effort made during the day.
Finding 3: perceived comfort beats calculated comfort
At equal temperature, occupants of the ventilated building report feeling more comfortable than those in the air-conditioned one. Air movement, even slight (0.3 m/s), changes everything. Adaptive comfort models predicted it; we measured it.
Limits
Three buildings is not a statistical sample. The raw data is available on request — we would rather it be discussed than believed.



Comments
Be the first to respond.